DoorKing 1812 Manual Overview

This section provides a general introduction to the DoorKing 1812 manual, encompassing both the Classic and Access Plus models. It outlines the purpose of the manual for installation, operation and maintenance. This includes key features of each model while highlighting the differences.

The DoorKing 1812 series encompasses two primary models⁚ the Classic and the Access Plus, each designed to meet varying access control needs. The Classic model, often referred to as the standard residential telephone intercom system, is built around the 1871-010 circuit board (Revision S or higher). It serves as a fundamental telephone entry system. Conversely, the Access Plus model represents an upgraded version, utilizing the 1970-010 circuit board (Revision M or higher). This enhanced model boasts additional capabilities and is PC programmable; Both models are designed for residential use, offering telephone intercom and access control. The manuals provide comprehensive instructions for the different circuit board revisions. The series is designed for sleek and timeless access control for homes and businesses, as they can be mounted in surface, flush and curved configurations. Both models provide secure and convenient access control through telephone intercom capabilities. These models are designed to integrate with gate and door systems.

1812 Classic Model⁚ Key Features and Specifications

The DoorKing 1812 Classic model, identified by its use of the 1871-010 circuit board (Revision S or higher), is a residential telephone intercom system designed for fundamental access control. It’s primarily intended for single-door or single-gate applications, providing basic telephone entry functions. The Classic model supports surface, wall, and flush mounting options, allowing flexible installation. It is commonly used to control access through a main entry point. Key features include standard telephone intercom functionality, enabling voice communication between visitors and residents. It’s designed to work as an entry system for a home or small business, enhancing security and convenience. The manual provides detailed instructions for installation and wiring of the 1812 Classic, ensuring proper setup. It is also compatible with accessories such as Remootio, for smartphone-based controls. This model’s specifications include its compatibility with DoorKing phone line surge suppressors. The Classic model is a reliable solution for basic access control requirements.

1812 Access Plus Model⁚ Functionality and Upgrades

The DoorKing 1812 Access Plus model, which uses the 1970-010 circuit board (Revision M or higher), expands upon the capabilities of the Classic model. This version is designed to control a main door or gate, along with up to six additional entry points via RS-485 communication. The Access Plus model is a PC-programmable residential telephone intercom and access control system, allowing for more complex configurations. It features advanced access control options. It also includes support for remote management via software, making it a more versatile solution. The Access Plus model is suitable for larger residential complexes or commercial settings requiring control over multiple entry points. This model also includes compatibility with various mounting options, including surface, wall, and flush mount. Surge protection is still recommended for the phone lines. The manual provides instructions for installing and wiring the Access Plus system, highlighting its upgraded functionality. This model offers enhanced control and management of access points.

Installation and Wiring

This section details the installation and wiring procedures for DoorKing 1812 models. It covers wiring multiple units, main terminal connector pin usage, and surge protection recommendations. Proper wiring is essential for optimal system performance and safety.

Wiring for Multiple 1812 Units

When installing multiple DoorKing 1812 units in a system, it’s crucial to understand the specific wiring requirements to ensure proper functionality and avoid potential issues. Each 1812 unit must be powered by its own dedicated power transformer; this is essential for maintaining consistent and reliable operation across all units. Interconnecting the units with a shared power source may lead to system instability or even damage to the components. Furthermore, it is highly recommended to implement surge protection for each unit within the system.

Specifically, surge suppressors should be used on both the phone in and phone out wires of every unit. This measure helps safeguard the system against voltage spikes, which can occur during electrical storms or other power fluctuations. Using DoorKing’s surge suppresser (p/n 1877-010) or an equivalent product is advisable to ensure the system’s durability. Proper wiring and surge protection practices are essential to maintain the longevity and reliability of your multi-unit DoorKing 1812 system.

In addition to the power and phone line considerations, be sure to connect the units using the appropriate communication wiring according to the manual. Each unit should be properly grounded to prevent issues related to electrical noise and static. Consulting the wiring diagrams in the manual is critical to ensure correct wiring and system integrity. Attention to these details will help prevent common issues and ensure the system operates as intended.

Main Terminal Connector⁚ Pin Usage

The main terminal connector on the DoorKing 1812 is a critical interface for connecting various devices and controlling gate or door access. This 18-pin jack serves multiple functions, with specific pins allocated for different purposes. It is essential to understand the pin usage to correctly wire the unit for the intended operation. It is important to note which pins are used for wiring your gate or door opener to the system. Pin numbers 11 through 16 are typically designated for controlling gate or door operation.

These pins can be associated with specific functions, such as gate activation, relay control, or other access-related commands. Accurate wiring based on the specific model and function is crucial for proper functionality. Incorrect connections can lead to system malfunctions or damage to the controller. Prior to wiring, carefully note or photograph the existing connections to ensure that the new wiring is performed correctly. This will help in avoiding confusion during installation or troubleshooting.

Additionally, the manual will provide a detailed diagram of the pin assignments and their associated functions, ensuring that the system is wired as designed. Always refer to the relevant manual to confirm the correct pin usage and avoid any errors. Proper connection to the correct pins is necessary for the unit to operate reliably and efficiently. Understanding the pin layout and its functions will help you maintain your system.

Surge Protection Recommendations

Protecting your DoorKing 1812 system from electrical surges is crucial for ensuring its longevity and reliable operation. The manual strongly recommends the use of surge protection devices, particularly for the phone line connections. Electrical surges, whether from lightning strikes or power grid fluctuations, can damage sensitive electronic components within the system. These surges can cause a loss of functionality, require costly repairs, or even necessitate complete replacement of the unit.

DoorKing specifically recommends using their phone line surge suppressor, part number 1877-010, or an equivalent device. The use of such suppressors on both the incoming and outgoing phone lines of the system is advised when dealing with multiple 1812 units in an interconnected system. This will help reduce the risk of damage across the interconnected units and protect every component. This level of protection will help to ensure that the system is protected from the negative effects of electrical surges.

The surge protection device should be installed in accordance with the manufacturer’s instructions. Regularly inspect the condition of your surge protection devices and replace them as needed. Consistent and proper maintenance of surge protection is crucial for the ongoing protection of your DoorKing 1812 system. By following these recommendations, you will maximize the performance and lifespan of the system and reduce potential down time. This will ensure a more reliable access control operation.

Troubleshooting and Support

This section offers guidance for resolving issues with your DoorKing 1812 system. It includes resources for technical support, documentation, and owners manuals. The purpose is to help users diagnose and fix problems efficiently.

Accessing Technical Support Documents and Downloads

This subsection details how users can access the necessary technical support documents and downloads for their DoorKing 1812 systems. DoorKing provides a comprehensive online resource center where users can find a variety of materials to aid in installation, programming, and troubleshooting. This includes manuals, specification sheets, and software updates. The technical support documents are designed to assist both installers and end-users in understanding the full capabilities of their system. Users can find these documents by visiting the official DoorKing website. The resources are categorized by product type, making it easy to locate the specific information needed for the 1812 Classic or Access Plus models. The website also offers video tutorials that provide step-by-step guidance on various procedures. This section also explains how to navigate the technical support section of the website to find the required information. This will ensure that users have access to the most up-to-date information to keep their systems running smoothly. In cases where users require further assistance, the website also provides contact information for direct support.

Finding Owners Manuals and Documentation

This section focuses on guiding users to locate the correct owner’s manuals and associated documentation for the DoorKing 1812 models. It emphasizes the importance of using the appropriate manual for your specific model, either the Classic or the Access Plus version, due to variations in functionality and circuit board revisions. The primary source for these documents is the DoorKing official website, where manuals are available in PDF format for easy download. These manuals provide detailed instructions regarding the system’s operation, programming, and troubleshooting. Users should verify that the manual corresponds to the circuit board revision of their system, as noted on the cover page. Different revisions may have different features, and using the wrong manual could lead to confusion. The documentation includes installation guides, wiring diagrams, and other useful resources. By utilizing the correct manual, users can ensure they are properly configuring and maintaining their DoorKing 1812 system. These documents should be kept in a safe location for future reference. The section also provides guidance on identifying the model and revision, to make sure you are using the correct version.

Leave a Reply